Biological Safety Cabinet
http://www.haiermedical.com/products/bio_safety_cabinet/biological_safety_cabinet/hr1200-iia2-d.html|| HR1200-IIA2-D|| HR1200-IIA2-D|| http://www.haiermedical.com/products/bio_safety_cabinet/biological_safety_cabinet/W020171121613591858135_362.png|| http://www.haiermedical.com/products/bio_safety_cabinet/biological_safety_cabinet/hr1200-iia2-d.html
http://www.haiermedical.com/products/bio_safety_cabinet/biological_safety_cabinet/hr1200-iia2-d.html
HR1200-IIA2-D
Biological Safety Cabinet
http://www.haiermedical.com/products/bio_safety_cabinet/biological_safety_cabinet/W020171121613591858135_362.png
http://www.haiermedical.com/products/bio_safety_cabinet/biological_safety_cabinet/W020171121613591858135_362.png
http://www.haiermedical.com/LocalLibrary/racks_boxes/
./

Biological Safety Cabinet HR1200-IIA2-D

 
  • HR1200-IIA2-D
  • HR1200-IIA2-D
  • HR1200-IIA2-D

Double Exhaust-Filters

Highly efficient HEPA’s dual output filtering structure provides an extra layer of protection. There is no need
for external wind pipe and no worry for lab pollution!

Two-Side Glass Walls

Two-side glass structure provides better lighting and larger operation space.

Compartmented Working Surface

The compartmented working surface can easily be removed for sterilization and bottom cleaning.

Safe Airflow System

The working space has airflow blocking design. The upper end of front window and the sides all have air curtain
protection to prevent cross flow between the inside and outside air and also contamination from spreading.

 
Pluggable Power Cable
Power cable can be changed according
to a user’s need.
 
LCD Display
LCD screen displays real time
operating parameters, filters
lifecycles and other critical
parameters.v
 
Water-Proof Socket
Standard water-proof socket, water valve and air valve.
 
Debris Grid
Debris grid catches debris such as paper scrap to damage negative pressure zone.
 
Glass Door
Drop-down glass door is easy to clean.
 
Adjustable Stand
Adjustable stand fits a customer’s need.

Technical Data

TypeClass II,Type A2

Electrical Data

Power (VA)1600(Active Power 200W)
Power of Blower(W)DC 190W,EC 170W
Main Filter Typical EffiencyULPA,U15,99.9995@0.12um
Exhaust Filter Typical EffiencyHEPA,H14,99.99@0.3um
Downflow Velocity(m/s)0.3
Inflow Velocity(m/s)0.45
Fluorescent Lamp Intensity(Lux)1000

Dimensions

Net/Gross Weight335/360 (kg) 738.5/793.7 (lbs)
Internal Dimensions(W*D*H)1310*620*630 (mm) 51.6*24.4*24.8 (in)
External Dimensions(W*D*H)1380*780*2160 (mm) 54.3*30.7*85.0 (in)
Packing Dimensions(W*D*H)1470*920*1690 (mm) 57.9*36.2*66.5 (in)
Supporter75-90mm adjustable height
Container loads (20'/40'/40'H)8/16/16

Function

AlarmSound and Flash

Others

CertificateEN12469    CE