Home Products Haier water purification systemCSJM-R Series Two Stage Reverse Osmosis Pure/Ultrapure Water System

CSJM-R Series Two Stage Reverse Osmosis Pure/Ultrapure Water System

Model Features Two-stage RO Purificatoin
Model CSJM-RRO
Feed water requirements * Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softenerrecommend when TDS>200 ppm )
Process Flow** PF+KDF+AC+RO+RO+AC
RO Water First stage RO water (TDS): Conductivity ≈ 5% source water conductivity; Second stage RO water (TDS): 1-5 µs/cm (conductivity≤% source water conductivity); Organic contaminants rejection>99% (when MW>200 Dalton); Particulates and bacteria rejection>99%
DI highly purified water RQ Series: Resistivity: 16-18.2 mΩ•cm, heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2μm)<1/ml
Ultrapurifiedwater R Series: Resistivity: 18.2 mΩ•cm (25°C), heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2μm)<1/ml, TOC<10 ppb ***, (UV/UVF Series: TOC<3 ppb***)
UF/UVF Series: Pyrogen<0.001 Eu/ml, RNases<0.01 ng/ml, DNases<4pg/μl
Water production rate (25°C) *** 15-20 L/h
Second stage instant dispensing rate 2.0 L/min
Water Outlets Two: Stage I, II RO water
Dimensions W*D*H: 500*360*540 mm, about 30 kg
Power supply/Power 220V/50Hz, 120W
Standard system configuration Water Purification Unit (with one set of purificationmodules), Tank Set (internal water level tank ×1 + 15 L external pressure tank × 1), accessories
Model Features Two-stage RO and DI purification
Model CSJM-RQ
Feed water requirements * Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softenerrecommend when TDS>200 ppm )
Process Flow** PF+KDF+AC+RO+RO+AC+DI+TF
RO Water First stage RO water (TDS): Conductivity ≈ 5% source water conductivity; Second stage RO water (TDS): 1-5 µs/cm (conductivity≤% source water conductivity); Organic contaminants rejection>99% (when MW>200 Dalton); Particulates and bacteria rejection>99%
DI highly purified water RQ Series: Resistivity: 16-18.2 mΩ•cm, heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2μm)<1/ml
Ultrapurifiedwater R Series: Resistivity: 18.2 mΩ•cm (25°C), heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2μm)<1/ml, TOC<10 ppb ***, (UV/UVF Series: TOC<3 ppb***)
UF/UVF Series: Pyrogen<0.001 Eu/ml, RNases<0.01 ng/ml, DNases<4pg/μl
Water production rate (25°C) *** 15-20 L/h
Second stage instant dispensing rate 2.0 L/min
Water Outlets Two: Stage II RO water, DI water
Dimensions W*D*H: 500*360*540 mm, about 30 kg
Power supply/Power 220V/50Hz, 120W
Standard system configuration Water Purification Unit (with one set of purificationmodules), Tank Set (internal water level tank ×1 + 15 L external pressure tank × 1), accessories
Model Features Two-stage RO ultrapurification
Model CSJM-R /UF /UV /UVF
Feed water requirements * Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softenerrecommend when TDS>200 ppm )
Process Flow** PF+KDF+AC+RO+RO (+UV)+AC+DI(+UF)+TF
RO Water First stage RO water (TDS): Conductivity ≈ 5% source water conductivity; Second stage RO water (TDS): 1-5 µs/cm (conductivity≤% source water conductivity); Organic contaminants rejection>99% (when MW>200 Dalton); Particulates and bacteria rejection>99%
DI highly purified water RQ Series: Resistivity: 16-18.2 mΩ•cm, heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2μm)<1/ml
Ultrapurifiedwater R Series: Resistivity: 18.2 mΩ•cm (25°C), heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2μm)<1/ml, TOC<10 ppb ***, (UV/UVF Series: TOC<3 ppb***)
UF/UVF Series: Pyrogen<0.001 Eu/ml, RNases<0.01 ng/ml, DNases<4pg/μl
Water production rate (25°C) *** 15-20 L/h
Second stage instant dispensing rate 2.0 L/min
Water Outlets Two: Stage II RO water, ultrapure water
Dimensions W*D*H: 500*360*540 mm, about 30 kg
Power supply/Power 220V/50Hz, 120W
Standard system configuration Water Purification Unit (with one set of purificationmodules), Tank Set (internal water level tank ×1 + 15 L external pressure tank × 1), accessories